Speco - A8P - Eight Door Controller with Lock Power

Part number:
Price:

Product Overview

**Panel Features** - Equivalent to having two A2E4Ps in one can - Contains two 4-door modules in one housing ​ - Each module can function as a “Server”, “Client” or “Elevator” ​ - Integrated 150-Watt power supply for complete system power​ - Wedge – Open enclosure design provides easy access to wiring​ - Lid removal disconnect pins for fast access to hardware​ - Tie downs support dual sided strapping for wire management - Cut Back Housing allows for wiring accessibility and easier to see your work​ - Mounting bar has wiring tie down slots for wire management on both sides of bar - ETL – UL 294 ​ - 5 year hardware warranty **Lock Power** - Lock power located on left/ right sides​ - 5’ IEC Cord Included​ - 8 Auto Resetting Fused Outputs​ - Isolated power for readers & controller​ - Selectable 12 or 24 VDC per output​ - LED status for voltage, power short and fire input triggered​ - Fire Drop Input​ - Power Supervision – log and action​ - Battery Backup (batteries not included)​ - Battery Backup for 12- and 24-volt outputs

 

Key Configuration

Model: A8P

 

Installation Notes

14.75" (W) × 14.75" (H) × 7" (D)

Full Specifications
ETL CertificationUL 294
Warranty5 years
Operating SystemEmbedded Linux
Transactions>60 per second
Power Requirements115VAC; standard wall plug in outlet
Operating Temperature50°F to 95°F (10°C to 35°C)
Enclosure Size14.75" (W) × 14.75" (H) × 7" (D)
Integrated Power Supply150W - IEC Cord; controller, readers and 12V and 24VDC for door locks
Power Output Spec *Per Output (4 outputs per module, 8 total)*12VDC 700mA, 24VDC 400mA
Battery BackupControllers, readers & door locks
Recommended Batteries2 total (batteries not included)
RJ485 / EthernetRequires two (2) TCIP connections and IP addresses; 1 per module
Readers (Wiegand)16 readers (1 in and 1 out reader for each door)
Reader Power300mA @ 12V max per reader 100mA @ 12V max per door panel
Request to Exit (REX) Inputs8 total (1 for each door)
Door Position (Status) Inputs8 total (1 for each door)
Auxiliary Input8 total (general purpose)
Tamper InputYes
Power Fault MonitoringYes
Door Lock Relays/Ratings8 Form C relay- 24V @ 2.0A / 12V @ 4.0A
Name
Description
Size
Downloads
File
Specification
0.4mb